Ebe nkesa usoro jụụ Ụdị dị ndụ

Ị na-ejikwa dock na ụlọ nchekwa jụụ nke ebe nkesa maka ngwaahịa nwere mmetụta okpomọkụ dị ka ọgwụ mgbochi. Ọnụ ụzọ meghere ọ bụla na-ahapụ ikuku ọkụ ịbanye, ụgbọ ala ọ bụla n'ahịrị bụ ibu na-eche, ngwaahịa ga-anọkwa n'etiti 2 °C na 8 °C.

Ihe ị ga-amụta

Simulator

Oge 0 min
Okpomọkụ ngwaahịa 5.0 °C · Ụgbọ ala na-eche 0 · Oge ụgbọ ala na-eche 0 min❄ 5.0 °C · 📦 5.0 °C · ⚡ 0.0 kW···✕✕✕🚚 0 · ⏱ 0 min
  • Ọnụ ụzọ efu
  • Na-ebupụ (ọnụ ụzọ meghere)
  • Ụgbọ ala na-eche
  • Reefer dara

Njikwa

Ọnụ ụzọ ọ bụla nwere ndị ọrụ na-ebupụ otu ụgbọ ala n'otu oge — ma na-ahapụ ikuku ọkụ ịbanye mgbe ọ meghere.

N'ime oke 2–8 °C. Dị ala na-enye ọtụtụ ọkpụkpọ mana na-eji ike karị.

Compressor abụọ, 40 kW nke ijụụ nke ọ bụla.

Na-ebelata ikuku ọkụ na-abanye n'ọnụ ụzọ meghere; ndị fan na-eji ike ụfọdụ.

Na-edebe ụgbọ ala nwere ngwa ijụụ dara n'ihu ahịrị.

Ihe ngosi

Okpomọkụ ngwaahịa
5.0°C
nkịtị
Oge ụgbọ ala na-eche
0min
nkịtị
Njigharị okpomọkụ
0.00°C·h
nkịtị
Ibu reefer dara
4.0°C
nkịtị
Ikuku ụlọ jụụ5.0 °C
Oge ndị ọrụ (awa ọnụ ụzọ nwere ndị ọrụ)0.5 h
Ụgbọ ala na-eche0
Ojiji dock0 %
Ike ijụụ0.0 kW

Ọnọdụ

Okpomọkụ ngwaahịa: — °C14.00.0

Ọnọdụ nsogbu

Ọkwa 1 · Compressor dara n'ụbọchị ọkụ

33 °C n'èzí, ụgbọ ala na-abịa kwụsiri ike, ọnụ ụzọ anọ meghere maka ibupụ. Otu n'ime compressor abụọ na-adị njikere ịda. Debe ọgwụ mgbochi n'ime 2–8 °C.

  • Ngwaahịa adịghị n'elu 8 °C
  • Ikuku ụlọ jụụ anaghị agafe mgbaama mbụ 7 °C (ntọala saịtị — echiche)
  • Oge ụgbọ ala na-eche n'ozuzu ≤ nkeji 60

Ọkwa 2 · Ọnụ ọgụgụ kachasị oge ememe

Awa anọ n'ime ụbọchị ọrụ awa 14, ọnụ kachasị nke oge ezumike na-amalite: maka awa asaa, ụgbọ ala 7 kwa awa na-abịa n'oge a debere — karịa okpukpu abụọ nke 3 a na-ahụkarị — ọnụ ụzọ atọ naanị nwere ndị ọrụ. Ndị ọkwọ ụgbọ debere oge nwere oge a kara aka, ya mere nkezi ichere ga-anọrịrị na nkeji 20 ma ọ bụ obere. Ndị ọrụ dock ọzọ dị njikere a kpọọ ha, mana mmefu ego oge ọzọ na-ekpuchi awa ọnụ ụzọ 68 nwere ndị ọrụ maka ụbọchị ahụ. Mepee ọnụ ụzọ ezuru n'oge — n'ejighị esi ụlọ jụụ n'ehihie 33 °C.

  • Oge ụgbọ ala na-eche n'ozuzu ≤ nkeji 20 site na ọnụ kachasị gaa n'ihu (oge a debere — oke siri ike)
  • Ngwaahịa adịghị n'elu 8 °C
  • Ike ijụụ n'ozuzu ≤ 55 kW
  • Oge ndị ọrụ ≤ awa ọnụ ụzọ 68 (mmefu ego oge ọzọ — echiche)

Ọkwa 3 · Reefer dara n'ogige

Ụgbọ ala iri na abụọ na-eche ugbu a, ọnụ ụzọ abụọ naanị nwere ndị ọrụ. Mgbe ahụ ngwa ijụụ nke ụgbọ ala n'azụ ahịrị anwụọ — na ọkụ 35 °C.

  • Ibu reefer dara adịghị n'elu 8 °C
  • Ngwaahịa dị n'ụlọ nchekwa adịghị n'elu 8 °C
  • Oge ụgbọ ala na-eche n'ozuzu ≤ nkeji 90

Ntọala — ụdị dị n'azụ ọnụọgụ

Mmekọrịta ọ bụla simulator na-eji, na isi mmalite ya. Ihe na-agbanwe agbanwe akara dị ka echiche bụ nhazi ngosi.

Nha okpomọkụ ụlọ jụụ: mgbidi na ọnụ ụzọ meghere na-ewebata okpomọkụ, ijụụ na-ewepụ ya.
C · dT/dt = UA·(T_out − T) + Q_door − Q_refrig[3][2]Echiche: oke okpomọkụ, nkwukọrịta mgbidi na ọnụ ụzọ, nha compressor na oge ọrụ bụ ụkpụrụ ngosi.
Ikuku na-abanye n'ọnụ ụzọ na-eto na ọnụọgụ ọnụ ụzọ meghere na ọdịiche okpomọkụ; mgbochi ikuku na-ebelata ya.
Q_door = n_open · 0.6 · 1.2 kW/K · (T_out − T) · (1 − 0.7·curtain)[2]Echiche: oke okpomọkụ, nkwukọrịta mgbidi na ọnụ ụzọ, nha compressor na oge ọrụ bụ ụkpụrụ ngosi.
Ọrụ ijụụ dị ka akụkụ nke oke Carnot.
COP = 0.45 · T_evap / (T_cond − T_evap) [K][4]
Okpomọkụ etiti ngwaahịa na-esochi ikuku na igbu oge awa abụọ.
T_product(t+Δt) = T_room + (T_product − T_room)·e^(−Δt/2h)[3]
Njigharị: awa-ogo n'èzí oke nchekwa 2–8 °C (ọkụ ma ọ bụ oyi kpọrọ nkụ).
excursion = Σ max(0, T − 8, 2 − T) · Δt [°C·h][1]
Ihe ndị ọzọ na-agbanwe agbanwe ejiri na ụdị a.
cold room 60 MJ/K, walls 0.6 kW/K · door open 60 % of unloading · air curtain −70 % infiltration, +3 kW fan per busy door · 2 × 40 kW compressors, −1 %/K above 32 °C · 4 kW per busy door (levellers, lights) · failed reefer τ = 3 h · scenario site settings: cold-room pre-alarm 7 °C, overtime budget 68 door-hours per 14 h day · booked trucks miss 5 % of slots · unloading Erlang-2Echiche: oke okpomọkụ, nkwukọrịta mgbidi na ọnụ ụzọ, nha compressor na oge ọrụ bụ ụkpụrụ ngosi.
Ụgbọ ala na-edebeghị oge na-abịa n'ụzọ enweghị usoro, ụgbọ ala debere oge na-abịa n'oge a kara aka ha (ole na ole na-atụfu ya), ọnụ ụzọ na-ejere ha ozi n'otu oge. Oge ichere na-eso iwu Little: ahịrị kewara site n'ụgbọ ala e budatara n'ezie kwa awa n'ime awa gara aga, ya mere ahịrị na-agbanweghị agbanwe anaghị awụli elu mgbe ọnụego ọbịbịa gbanwere.
arrivals ~ Poisson(λΔt) + booked slots (5 % no-show), service ~ Erlang-2 (mean 45 min), c staffed doors; X = n_busy / 45 min (smoothed, τ = 1 h); W_q = L_q / X[6][5]
Oge ndị ọrụ: a na-akwụ ụgwọ maka ọnụ ụzọ ọ bụla nwere ndị ọrụ, ma ụgbọ ala nọ ya ma ọ bụ na ọ nọghị.
crew time = Σ c_staffed · Δt [door-hours]

Enweghị usoro: ihe mmepụta mulberry32 nwere mkpụrụ; nkesa ejiri — uniform, exponential (inverse CDF), normal (Box–Muller), Poisson (Knuth). A na-egosi mkpụrụ ma nwee ike ikekọrịta ya.

Isi mmalite

  1. PAHO — Cold chain: vaccines are stored and transported between +2 °C and +8 °C — Pan American Health Organization
  2. ASHRAE Handbook — Refrigeration, ch. 24 Refrigerated-Facility Loads (door infiltration, Gosney–Olama model; air curtains) — ASHRAE, 2022
  3. F. P. Incropera et al. — Fundamentals of Heat and Mass Transfer: lumped capacitance — Wiley, 2011
  4. Y. A. Çengel, M. A. Boles — Thermodynamics: Carnot COP of refrigerators — McGraw-Hill, 2019
  5. J. D. C. Little — A Proof for the Queuing Formula L = λW — Operations Research 9(3), 1961
  6. D. Gross, C. M. Harris — Fundamentals of Queueing Theory (M/M/c) — Wiley, 2008

Ndị na-arụ nke a dị ka ọrụ

Ụdị agụmakwụkwọ — ọ bụghị maka mkpebi ọrụ. Ebe n'ezie na-edozi ihe niile na-agbanwe agbanwe dịka ngwá ọrụ na data nke ha si dị.